SUN-30K-SG01HP3-EU-BM3

Hoʻokaʻawale-ʻano home mālama ikehu inverter

Hoʻokaʻawale-ʻano home mālama ikehu inverter

SUN-30K-SG01HP3-EU-BM3

SUN-29.9/30/35K-SG01HP3-EU-BM3
SUN-40/50K-SG01HP3-EU-BM4

NA MEA HANA

  • 100% ka hoʻopuka kaulike ʻole, kēlā me kēia māhele

  • ʻO nā kāne AC e hoʻihoʻi hou i ka ʻōnaehana solar

  • Max. 10 pcs parallel no ka hana on-grid a me waho-grid; Kākoʻo i nā ʻōhua pākahi like ʻole

  • Max. hoʻouka / hoʻokuʻu i kēia manawa o 100A

  • Kiʻekiʻe voltage pākaukau, ʻoi aku ka maikaʻi

  • Kākoʻo i ka mālama ʻana i ka ikehu mai ka mīkini hana diesel

NA PALAPALA HUA

Hoʻohālike SUN-29.9K-SG01HP3
-EU-BM3
SUN-30K-SG01HP3
-EU-BM3
SUN-35K-SG01HP3
-EU-BM3
SUN-40K-SG01HP3
-EU-BM4
SUN-50K-SG01HP3
-EU-BM4
ʻIkepili Hoʻokomo Bateri
ʻAno Bateri Lithium-ion
Laulā Voltage Battery (V) 160-800
Max. Hoʻouka ʻia i kēia manawa (A) 50+50
Max. Ke hoʻokuʻu nei i kēia manawa (A) 50+50
Hoʻolālā Hoʻouka no ka Battery Li-ion Hoʻololi ponoʻī iā BMS
Ka helu o ka hoʻokomo ʻana i ka Bati 2
PV String Ikepili Hookomo
Max. Mana Loaʻa PV (W) 59800 60000 70000 80000 100000
Max. Mana Hookomo PV (W) 47840 48000 56000 64000 80000
Max. Voltage Hookomo PV (V) 1000
HoʻomakaVoltage (V) 180
Māhele Voltage MPPT (V) 150-850
Ka Voltage Hookomo PV (V) 600
Max. Manaʻo PV hoʻokomo i kēia manawa (A) 36+36+36 36+36+36+36
Max. Hoʻokomo ʻia ka ʻĀpana Pōkole (A) 55+55+55 55+55+55+55
Ka helu o nā MPP Trackers/
Ka helu o nā kaula MPP Tracker
3/2+2+2 4/2+2+2+2
ʻIkepili Hoʻokomo / Hoʻopuka AC
Mana Mana Hoʻokomo/Hanaʻike AC i koho ʻia (W) 29900 30000 35000 40000 50000
Max. Mana Hoʻokomo/Hanaʻike AC (VA) 29900 33000 38500 44000 55000
Hoʻokomo ʻia ʻo AC/Hana i kēia manawa (A) 45.4/43.4 45.5/43.5 53.1/50.8 60.7/58 75.8/72.5
Max. Kokohu AC/Hana i kēia manawa (A) 45.4/43.4 50/47.9 58.4/55.8 66.7/63.8 83.4/79.8
Max. Hoʻomau ʻia ʻo AC Passthrough (grid to load) (A) 200
Mana Kiʻekiʻe (waho-puʻu) (W) 1.5 manawa o ka mana helu, 10s
Kaulana Hoʻoponopono Mana Mana 0.8 e alakaʻi ana i ka 0.8 lagging
Hoʻokohu ʻia ka Voltage/Wowput Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Hoʻokolo ʻia ka helu hoʻokomo/kumu puka alapine (Hz) 50/45-55, 60/55-65
Puka Hoʻohui Grid 3L+N+PE
Huina o Harmonic distortion o keia manawa THDi <3% (o ka mana helu)
ʻO ke ʻano hoʻoheheʻe DC <0.5% In
fficience
Max. Ka pono 97.60%
Hoʻoikaika Euro 97.0%
MPPTEkupono >99%
Palekana lako
Hoʻohui ʻia ʻO DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
Palekana ʻAha Puke AC, Palekana Kaapuni Pōkole AC Output, Mākaʻikaʻi ʻĀpana DC,
Hoʻopalekana Hoʻokuʻu ʻO Overvoltage Load Drop, Ka nānā ʻana i kēia manawa hewa ʻole, Arc Fault Circuit Interrupter (koho),
Ka nānā ʻana i ka pūnaewele mana, ka nānā ʻana i ka mālama ʻana i ka mokupuni, ka ʻike hewa honua, DC Input Switch,
DC Terminal Insulation Impedance Monitoring, Ke koena o kēia manawa (RCD) Detection, Surge pale pae
Ka Papa Hoʻomalu ʻAha ANO II(DC), ANO II(AC)
Ikepili
Pāʻani Kūkākūkā RS485/RS232/CAN
ʻAno nānā GPRS/WIFI/Bluetooth/4G/LAN (koho)
ʻIkepili Nui
Ka Wehewela Hana (℃) -40 a +60 ℃, > 45 ℃ Derating
ʻAe ʻia ka haʻahaʻa ambient 0-100%
ʻAe ʻia ke kiʻekiʻe 2000m
Halau (dB) ≤65
ʻO ka helu hoʻomalu ʻana (IP). IP 65
Topology Inverter Kaʻawale ʻole
Ma luna o ka Voltage Category OVC II(DC), OVC III(AC)
Nui o ke Kuhina (WxHxD mm) 527×894×294 (Kae ʻole nā ​​mea hoʻohui a me nā pale)
Kaumaha (kg) 80
ʻAno hoʻoluʻu ʻO ka hoʻoluʻu ea akamai
Palapala hōʻoia 5 Makahiki/10 Makahiki
ʻO ka manawa o ka Warranty e pili ana i ka pūnaewele hoʻokomo hope o Inverter, ʻike hou aku e ʻoluʻolu e nānā i ke kulekele Warranty
Hooponopono Grid IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99,VDE-AR-N 4105
Palekana / EMC Kūlana IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

HANA PILI

  • HSI 5500

    HSI 5500

  • Axpert VM Il Premium 3K

    Axpert VM Il Premium 3K

  • SPI-10K-S

    SPI-10K-S