Model | SUN-29,9K-SG01HP3 -EI-BM3 | SUN-30K-SG01HP3 -EI-BM3 | SUN-35K-SG01HP3 -EI-BM3 | SUN-40K-SG01HP3 -EI-BM4 | SUN-50K-SG01HP3 -EI-BM4 |
Batareya kiritish ma'lumotlari | |
Batareya turi Lityum-ion |
Batareya kuchlanish diapazoni (V) | 160-800 |
Maks. Zaryadlash oqimi (A) | 50+50 |
Maks. Bo'shatish oqimi (A) | 50+50 |
Li-ion batareyasi uchun zaryadlash strategiyasi | O'z-o'zini BMSga moslashtirish |
Batareya kiritish soni | | 2 | |
PV string kirish ma'lumotlari | |
Maks. PV kirish quvvati (Vt) | 59800 | 60 000 | 70 000 | 80 000 | 100000 |
Maks. PV kirish quvvati (Vt) | 47840 | 48000 | 56000 | 64000 | 80 000 |
Maks. PV kirish kuchlanishi (V) | | | 1000 | |
Ishga tushirish kuchlanishi (V) | 180 |
MPPT kuchlanish diapazoni (V) | 150-850 |
Nominal PV kirish kuchlanishi (V) 600 |
Maks. Ishlaydigan PV kirish oqimi (A) | 36+36+36 | 36+36+36+36 |
Maks. Kirish qisqa tutashuv oqimi (A) | 55+55+55 | 55+55+55+55 |
MPP Trackers soni/ Satrlar soni MPP Tracker | 3/2+2+2 | 4/2+2+2+2 |
AC kirish/chiqish ma'lumotlari | | |
Nominal AC kirish/chiqish faol quvvati (Vt) | 29900 | 30 000 | 35000 | 40000 | 50 000 |
Maks. AC kirish/chiqish koʻrinadigan quvvati (VA) | 29900 | 33000 | 38500 | 44000 | 55000 |
Nominal o'zgaruvchan tokning kirish/chiqish oqimi (A) | 45,4/43,4 | 45,5/43,5 | 53,1/50,8 | 60,7/58 | 75,8/72,5 |
Maks. AC kirish/chiqish oqimi (A) | 45,4/43,4 | 50/47,9 | 58,4/55,8 | 66,7/63,8 | 83,4/79,8 |
Maks. Uzluksiz AC o'tish (tormozdan yuklash uchun) (A) 200 |
Eng yuqori quvvat (tarmoqsiz) (Vt) | Nominal quvvatning 1,5 barobari, 10s |
Quvvat faktorini sozlash diapazoni | 0,8 0,8 ortda qolishga olib keladi |
Nominal kirish/chiqish kuchlanishi/diapazoni (V) | 220/380V, 230/400V 0,85Un-1,1Un |
Nominal kirish/chiqish tarmoq chastotasi/diapazoni(Hz) | 50/45-55, 60/55-65 |
Tarmoq ulanish shakli | 3L+N+PE |
Jami joriy garmonik buzilish THDi | <3% (nominal quvvatdan) |
DC qarshi oqimi | <0,5% In |
Samaradorlik |
Maks. Samaradorlik | 97,60% |
Evro samaradorlik | 97,0% |
MPPTE samaradorligi | >99% |
Uskunani himoya qilish |
Integratsiyalashgan | DC qutbli teskari ulanishni himoya qilish, AC chiqish haddan tashqari oqimdan himoya qilish, termal himoya, AC chiqishi haddan tashqari kuchlanishdan himoya qilish, AC chiqishi qisqa tutashuvidan himoya qilish, shahar komponentlarini monitoring qilish, Haddan tashqari kuchlanish yukining tushishidan himoya qilish, tuproqdagi nosozliklar oqimi monitoringi, yoyning noto'g'ri tutashuvini to'xtatuvchisi (ixtiyoriy), Elektr tarmog'i monitoringi, Orolni himoya qilish monitoringi, Yerdagi nosozliklarni aniqlash, DC kirish kaliti, DC terminali izolyatsiyalash empedansini kuzatish, qoldiq oqim (RCD) aniqlash, kuchlanishdan himoya darajasi |
Kuchlanishdan himoyalanish darajasi | TYPE II (DC), TYPE II (AC) |
Interfeys |
Aloqa interfeysi | RS485/RS232/CAN |
Monitor rejimi | GPRS/WIFI/Bluetooth/4G/LAN (ixtiyoriy) |
Umumiy ma'lumotlar |
Ishlash harorati oralig'i (℃) | -40 dan +60 ℃ gacha, >45 ℃ deting |
Ruxsat etilgan atrof-muhit namligi | 0-100% |
Ruxsat etilgan balandlik | 2000 m |
Shovqin (dB) | ≤65 |
Kirish himoyasi (IP) reytingi | IP 65 |
Inverter topologiyasi | Izolyatsiya qilinmagan |
Haddan tashqari kuchlanish toifasi | OVC II (DC), OVC III (AC) |
Shkaf hajmi (GxYxD mm) | 527×894×294 (Ulagichlar va qavslardan tashqari) |
Og'irligi (kg) | 80 |
Sovutish turi | Intellektual havo sovutish |
Kafolat | 5 yil / 10 yil Kafolat muddati inverterni oxirgi o'rnatish joyiga bog'liq, batafsil ma'lumot Kafolat siyosatiga qarang |
Tarmoqni tartibga solish | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
Xavfsizlik / EMC standarti | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |