Adopts independent liquid cooling/air cooling dual cooling solutions (optional selection as required)
Equipped with compartment physical isolation, suitable for stable heat dissipation of large-capacity energy storage
Full-range battery cell temperature collection combined with AI predictive monitoring enables early warning of abnormalities
Compatible with multiple communication interfaces including LAN/CAN/RS485, allowing remote monitoring of operating status
Capacity covers an ultra-wide range from 2170kWh to 5015kWh
Supports customized busbar output, compatible with various PCS access and configuration schemes
| Battery Container Product Parameters | ||
| Equipment Model | ICS-DC 2170/A/10 | ICS-DC 2351/L/15 |
| Cell Parameters | ||
| Cell Specifications | 3.2V/314Ah | |
| Battery Type | LFP | |
| Battery Module Parameters | ||
| Packaging Configuration | 1P16S | 1P52S |
| Nominal Voltage | 51.2V | 166.4V |
| Nominal Capacity | 16.076kWh | 52.249kWh |
| Nominal Charge/Discharge Current | 157A | |
| Nominal Charge/Discharge Rate | 0.5C | |
| Cooling Method | Air Cooling | Liquid Cooling |
| Battery System Parameters | ||
| Maximum Number of Battery Clusters | 9 | 9 |
| Nominal Voltage | 768V | 832V |
| Nominal Capacity | 2170.368kWh | 2351.232kWh |
| Voltage Range | 696~852V | 754V~923V |
| Nominal Charge/Discharge Current | 1256A | 1413A |
| Nominal Charge/Discharge Rate | 0.5C | |
| Cooling Method | Air Cooling | Liquid Cooling |
| Fire Protection | Perfluorohexanone / Heptafluoropropane / Aerosol (Optional) | |
| Smoke Detection & Temperature Detection | Per Cluster: 1 Smoke Detector, 1 Temperature Detector | |
| Basic Parameters | ||
| Communication Interface | LAN/RS485/CAN | |
| IP Rating | IP54 | |
| Operating Ambient Temperature Range | -25℃~+55℃ | |
| Storage Temperature Range | -20~45℃ (1 month) / 0~35℃ (3 months) | |
| Relative Humidity | ≤95% RH, Non-condensing | |
| Altitude | 3000m | |
| Noise Level | ≤70dB | |
| Dimensions (mm) | 6058*2438*2896 | |